Brand: URANUSOrigin: TurkeyCategory: Fire Resistant Cables

URANUS BM30 FE180 PH30

Fire resistant cable: solid copper, silicone insulation, ALPET foil screen, 300/500 V. Certified by LPCB.

URANUS BM30 FE180 PH30 is a halogen-free, flame-retardant, low-smoke fire resistant cable certified by LPCB, with an ALPET foil screen and twisted, silicone-insulated solid copper conductors. For fire alarm, emergency lighting and other life-safety circuits.

Approvals

LPCB

From Falcon's approvals register. View register

Need this product?

Send quantities, sizes and your required date. We reply with availability and pricing.

Features and advantages

  • Flexible — very flexible construction that makes installation easier in all conditions
  • LSZH (low smoke zero halogen) — very low toxicity, low smoke emission and no corrosive gas, safeguarding human life and electronic equipment
  • Flame retardant — limits the spread of fire along the cable run
  • Protected against electrostatic noise — fully screened, with twisted conductors
  • Moisture resistant — no special terminals needed to prevent moisture absorption; can be installed in damp environments
  • Suitable for data transmission — twisted conductors give clear transmission

Applications

  • Machines and equipment that must keep working during a fire (emergency elevators, fire water pumps)
  • Ventilation systems connected to the fire alarm system
  • Emergency lighting at fire escape exits
  • Emergency power supplies
  • Places where human life and valuable materials and equipment need to be protected

Technical specifications

Construction
PropertyValue
ConductorElectrolytic solid copper wire (IEC 60228 / DIN EN 60228 / EN 60228 Class 1)
InsulationEN 50363-1 EI2 silicone compound
Core identificationHD 308 S2 (see colour code)
Lay-upCores stranded in layers
Overall screenALPET foil
SheathHalogen-free flame-retardant compound (HFFR / LSHF / FRNC)
Sheath colourRed (RAL 3000) or white (RAL 9003)
Drain wire0.80 mm solid tinned copper wire
Technical properties
PropertyValue
Operating voltage300/500 V
Test voltage2 kV
Insulation resistancemin. 200 MΩ × km
Temperature rangeOperation: −30 °C to +90 °C · Installation: −5 °C to +60 °C
Min. bending radiusOperation: 8 × cable diameter · Installation: 15 × cable diameter
Flame resistant testIEC 60332-1-2
Flame propagation test (Cat A)IEC 60332-3-24
Smoke density testIEC 61034-1/2
Halogen-free testIEC 60754-1
Corrosive gas testIEC 60754-2, BS/EN 50267
Circuit integrity with shock and water (C, W, Z)BS 6387:2013
Circuit integrity test (FE180)IEC 60331-21
Circuit integrity with shock test (PH30)EN 50200 PH30
Dimensions, resistance and weight
Cross sectionApprox. overall diameter (mm, ±10%)Conductor resistance (Ω/km)Approx. weight (kg/km)
2 × 1.5 mm²6.7012.167
3 × 1.5 mm²7.1012.185
4 × 1.5 mm²7.9012.1109
2 × 2.5 mm²7.907.4194
3 × 2.5 mm²8.407.41125
4 × 2.5 mm²9.207.41156
Core colour code (HD 308 S2)
CoresColours
2 coreBlue, brown
3 coreBrown, black, grey
4 coreBlue, brown, black, grey
Applicable standards
Standard
BS 6387:2010 (Category CWZ)
IEC 60331-21:1999
EN 50200:2015 (Class PH30)
EN 60754-1:2014
EN 60754-2:2014
EN 61034-2:2005+A1:2013
Typical applications — design standards
StandardScope
BS 5839-1Fire detection and fire alarm systems for buildings — code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS 5839-8Fire detection and fire alarm systems for buildings — code of practice for design, installation, commissioning and maintenance of voice alarm systems
BS 5839-9Fire detection and fire alarm systems for buildings — code of practice for design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 5266-1Emergency lighting — code of practice for the emergency lighting of premises
BS 8519Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications